Shop By Category

Humidity chamber HCP 107l

Product Code: MMTHCP105

Increase value Decrease value
  • Overview
  • Specifications
  • Contact us
  • Attachments
Overview

Humidity chamber HCP 107L

Perfect environmental simulation in the humidity chamber

This climate chamber offers the full range of comfort, reliability, and safety. It has active humidity control set from 20 % to 95 % rh and an unsurpassed homogeneity of temperature and humidity over the entire interior. It is suited for environmental testing, environmental simulation, accelerated service life tests, and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.

  • Temperature range up to +90 °C
  • Four model sizes (56 to 241 litres volume)
  • One model variant: TwinDISPLAY
  • Active humidity control 20 to 95 % rh
  • Double doors as standard:
  1. Prevention of contamination
  2. Prevention of drops or rises in temperature
  3. An optimal view of the sensitive chamber load through wide-area heated inner glass door

Humid environment without condensation

The active humidity control ensures an ideal homogeneity of temperature, humidity as well as short recovery times after opening the door. It is practically a maintenance-free climate chamber.

In combination with the heating on all six sides, including a heated inner glass door, it also minimises vaporisation in the interior and, thus, the risk of condensed water dripping onto the test object.

An aluminium thermal conductive layer supports optimum temperature distribution and serves as a heat accumulator in case of a temporary power failure.

Comfortable equipment for accelerated service life tests

To ensure that environmental tests and accelerated life tests such as 85/85 tests run reliably and safely, the humidity chamber HCP offers a wide range of comfort functions:

  1. Standard feed-through on the rear panel
  2. Battery-buffered ControlCOCKPIT (option)
  3. Process runtime starts with SetpointWAIT function only when the setpoint temperature is reached
  4. Alarm messages can be sent via e-mail or SMS with MobileALERT (option) and much more.

A Memmert humidity chamber offers unique advantages

  • Intuitive and easy-to-use operating menu
  • Heating concept specifically adapted for a precise and homogenous temperature control
  • A wide range of options for programming and documentation of different temperature/humidity profiles via Software AtmoCONTROL
  • Alarm functions, three-fold overtemperature protection and simultaneous display of all parameters provide safety for samples and cell cultures
  • Almost exclusive use of high-quality and easily cleanable stainless steel for the working chamber and housing
  • Three years guarantee worldwide
Technical Specifications
Supplier Memmert

HCP105

Standard delivery Humidity chamber

On this page, you can find all the essential technical data on the Memmert humidity chamber HCP. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at info@labsupply.co.nz 


Sketch Humidity chamber HCP105


Temperature

Working-temperature range +7 above ambient temperature up to +90 °C
Setting temperature range +18 to +90 °C
Setting accuracy temperature 0.1 °C
Temperature sensor 2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Humidity

Humidity Control Active microprocessor control for humidifying and dehumidifying (20 – 95 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times. Humidity supply with water (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7; from an external tank) by a self-priming pump; integral bacteria block by generating hot steam, dehumidifying via sterile filter
Setting range active humidity control 20 to 95 % rh and rh-Off
Setting accuracy humidity 0.5 % rh

Control technology

ControlCOCKPIT TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays.
Language setting German, English, Spanish, French, Polish, Czech, Hungarian
adjustable parameters temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones, summertime/wintertime
Timer Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT the process time does not start until the set temperature is reached
Calibration three freely selectable values each, temperature and humidity

Communication

Interface Ethernet LAN, USB
Documentation programme stored in case of power failure
Programming AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

Safety

AutoSAFETY additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature
Autodiagnostic system integral fault diagnostics for temperature and humidity control
Alarm visual and acoustic

Heating concept

6 sides large-area multi-function heating system on four sides with additional door and back heating to avoid condensation

Standard equipment

Works calibration certificate Works calibration certificate (measuring point chamber centre) at 60 °C with 75 % rh
Door Additional heated inner glass door
Door fully insulated stainless steel door with 2-point locking (compression door lock)
Entry port Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, centre left
Internals 2 perforated stainless steel shelf/shelves
Standard accessories Water tank including connection hose

Stainless steel interior

Dimensions w(A) x h(B) x d(C): 560 x 480 x 400 mm (d less 35 mm for fan)
Interior W.-St. 1.4301 (ASTM 304)
Volume 107 l
Max. number of internals 6
Max. loading of chamber 90 kg
Max. loading per internal 15 kg

Textured stainless steel casing

Dimensions w(D) x h(E) x d(F): 719 x 850 x 591 mm (d +56mm door handle)

Electrical data

Voltage Electrical load 230 V, 50/60 Hz
approx. 1720 W
Voltage Electrical load 115 V, 50/60 Hz
approx. 1720 W

Ambient conditions

Ambient temperature 10 °C to 30 °C
Set Up The distance between the wall and the rear of the appliance must be at least 15 cm. The clearance from the ceiling must not be less than 20 cm and the side clearance from walls or nearby appliances must not be less than 5 cm.
Humidity rh max. 70 %, non-condensing
Altitude of installation max. 2,000 m above sea level
Overvoltage category II
Pollution degree 2

Packing/shipping data

Transport information The appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton w x h x d: 800 x 1030 x 800 mm
Net weight approx. 75 kg
Gross weight carton approx. 100 kg
Contact Us
Captcha Image
Signature
Products to compare:
Comparing Products